What it means
Compressor stops. Activated when the temperature on sensor T6 exceeds the applicable maximum hot gas temperature.
Source: Worcester Greenstore LECP Installation, Commissioning and Servicing Instructions 6 720 806 768 (2013/02), §21.8 categories + §21.10 alarm functions + §21.13 information log (render-verified)
Can it be reset?
Category A — Stops compressor; lamp+buzzer; 5 s delay; acknowledgement required. Resets when: The hot gas temperature drops 5K below the alarm limit.
Source: Worcester Greenstore LECP Installation, Commissioning and Servicing Instructions 6 720 806 768 (2013/02), §21.8 categories + §21.10 alarm functions + §21.13 information log (render-verified)
UK models this code applies to
Tap yours to open E2X.T6 on that machine.
Now the harder half: proving what caused it
E2X.T6 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase E2X.T6 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Related codes
- E1X.T1High flow temperature
- E2X.RHPTripped high pressure switch
- E2X.RLPTripped low pressure switch
- E2X.T8High flow temperature E2X.T8 (information)
- E21.E2Faulty electric heater
- E21.RHPTemporary heat pump stop E21.RHP (information)
- E21.RLPTemporary heat pump stop E21.RLP (information)
- E41.F31Faulty protective anode