Outdoor return signal stops (with TE/TC high temperature)
Block 03. As 07, but recorded after 11 detections, and the manual adds a high TE/TC temperature cause — TE in cooling, TC in heating. That points at heat-exchanger fouling rather than a purely electrical fault.
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
UK models this code applies to
From the Toshiba service literature we hold (Toshiba service manual SVM-19001-3 (Seiya) / SVM-20015-4 (Shorai Edge) §11-4, Table 11-4-1) — not a scraped list.
21 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.