LG Therma V CH19 fault code
LG Therma V heat pumps
What the LG Therma V CH19 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The electric-heater outlet sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
Likely causes
- Loose or corroded connector
- Faulty thermistor
- PCB fault
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
UK models this code applies to
Tap yours to open CH19 on that machine.
Hydro units and cylinders1
Outdoor units36
Now the harder half: proving what caused it
CH19 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase CH19 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- CH14Flow rate alarm
- CH15Water-pipe overheating
- CH16Combined water-sensor fault (CH17 + CH18 + CH19 together)
- CH17Water-outlet sensor open/short
- CH18Electric backup-heater outlet sensor open/short
- CH20Electric heater overheated (thermal cut-out / fuse blown)
- CH21DC peak / IPM fault (compressor stopped on power-module Fault-Out)
- CH22CT current error (outdoor over-current)
- CH23DC-link over/under-voltage
- CH24High-pressure error (discharge pressure excessive)