LG Therma V CH15 fault code
LG Therma V heat pumps
What the LG Therma V CH15 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Water-pipe temperature has exceeded LG's limit — almost always a starved circuit or an over-high leaving-water target, not a component failure.
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
Likely causes
- Low water flow (pump, strainer, air, closed valve)
- Leaving-water setpoint too high
- Water-outlet sensor drift
- PCB fault
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
UK models this code applies to
Tap yours to open CH15 on that machine.
Hydro units and cylinders1
Outdoor units36
Now the harder half: proving what caused it
CH15 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase CH15 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- CH06Refrigerant outlet-pipe sensor (indoor) open/short
- CH08DHW tank sensor open/short
- CH09Indoor PCB EEPROM fault
- CH13Solar-thermal sensor problem
- CH14Flow rate alarm
- CH16Combined water-sensor fault (CH17 + CH18 + CH19 together)
- CH17Water-outlet sensor open/short
- CH18Electric backup-heater outlet sensor open/short
- CH19Electric backup-heater outlet sensor open/short (printed as CH18's…
- CH20Electric heater overheated (thermal cut-out / fuse blown)