LG Therma V CH24 fault code
LG Therma V heat pumps
What the LG Therma V CH24 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: High-side pipework will be hot — take care.
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
Likely causes
- Poor condenser heat rejection (coil / fan / airflow)
- Overcharge or non-condensables
- Stop valve part-closed
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
UK models this code applies to
Tap yours to open CH24 on that machine.
Hydro units and cylinders1
Outdoor units36
Now the harder half: proving what caused it
CH24 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase CH24 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- CH19Electric backup-heater outlet sensor open/short (printed as CH18's…
- CH20Electric heater overheated (thermal cut-out / fuse blown)
- CH21DC peak / IPM fault (compressor stopped on power-module Fault-Out)
- CH22CT current error (outdoor over-current)
- CH23DC-link over/under-voltage
- CH26No-position error (compressor initial start abnormal)
- CH27PFC over-current
- CH29Compressor over-current (inverter input over limit)
- CH32Discharge-pipe temperature high
- CH34High-pressure error (condensing pressure high)