What it means
The outdoor th-series sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
How to read it — ftc controller: Ecodan check codes show on the FTC / main controller display. (Ecodan service manual OCH727, §9-2 self-diagnosis action table)
Source: Ecodan service manual OCH727 §9-2
Likely causes
- Loose or corroded connector
- Faulty thermistor
- PCB fault
Source: Ecodan service manual OCH727 §9-2
UK models this code applies to
U4 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units44
Now the harder half: proving what caused it
U4 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase U4 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- P1Room temperature thermistor (TH1A/TH1B) open/short
- P2Liquid refrigerant thermistor (TH2) open/short
- P6Plate heat-exchanger freeze protection
- P8Refrigerant circuit abnormality
- U1High pressure (high-pressure switch 63H operated)
- U2Abnormal high discharge temperature
- U3Discharge thermistor (TH4) open/short
- U8Outdoor fan motor abnormality
- U9Supply voltage abnormality (over/under-voltage)
- UFCompressor over-current