All fault codes

Mitsubishi Ecodan E3 fault code

Mitsubishi Ecodan heat pumps

What it means

Main controller transmission failure

The main controller cannot find a clear transmission path for 6 s, or its data readback mismatches 30 times running. Classic cause: two main controllers wired to one FTC.

Safety: Safe isolation before opening terminal covers — mains present on the interconnect.

UK models this code applies to

From the Mitsubishi Electric service literature we hold (Ecodan FTC service manual, error-code chapter + §10-6 thermistor tables) — not a scraped list.

Ecodan PUZ-WM50VHA (R32)Ecodan PUZ-WM60VAA (R32)Ecodan PUZ-WM85VAA (R32)Ecodan PUZ-WM85YAA 3-phase (R32)Ecodan PUZ-WM112VAA (R32)Ecodan PUZ-WM112YAA 3-phase (R32)Ecodan PUZ-WZ50VAA (R290)Ecodan PUZ-WZ60VAA (R290)Ecodan PUZ-WZ85VAA (R290)Ecodan PUZ-WZ85YAA 3-phase (R290)Ecodan PUZ-WZ100VAA (R290)Ecodan PUZ-WZ100YAA 3-phase (R290)Ecodan PUZ-WZ120VAA (R290)Ecodan PUZ-WZ120YAA 3-phase (R290)

Now the harder half: proving what caused it

E3 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase this code in the app →

Other Mitsubishi Ecodan codes