Vaillant aroTHERM F.042 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.042 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The coding resistor is damaged or has not been set. The manual's remedy: check that the coding resistor is correct and fitted — this catches a replacement board or unit that was never coded to the installation.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p57.
- Coding resistor damaged or not set
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Check that the coding resistor is positioned correctly and, if required, replace it.
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p57.
UK models this code applies to
Tap yours to open F.042 on that machine.
F.042 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.042 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.042 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.022Heating water pressure too low
- F.073Building-circuit water pressure sensor fault
- F.514Compressor inlet temperature sensor
- F.517Compressor outlet temperature sensor
- F.519Building circuit return temperature sensor
- F.520Building circuit flow temperature sensor
- F.526EEV outlet temperature sensor fault
- F.546High-pressure sensor fault
- F.582Electronic expansion valve fault
- F.585Condenser outlet temperature sensor fault