All fault codes

Vaillant aroTHERM F.042 fault code

Vaillant aroTHERM heat pumps

What it means

Coding resistor fault

The coding resistor is damaged or has not been set. The manual's remedy: check that the coding resistor is correct and fitted — this catches a replacement board or unit that was never coded to the installation.

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W, Toshiba approx. 100 Ω 40 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

UK models this code applies to

From the Vaillant service literature we hold (Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table) — not a scraped list.

aroTHERM plus VWL 35/6aroTHERM plus VWL 55/6aroTHERM plus VWL 75/6aroTHERM plus VWL 105/6aroTHERM plus VWL 125/6

Now the harder half: proving what caused it

F.042 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase this code in the app →

Other Vaillant aroTHERM codes