Panasonic air conditioning F97 fault code
Panasonic air conditioning
What the Panasonic air conditioning F97 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Compressor tank temperature reaches ~112°C and the unit protects.
Safety: Discharge pipework runs very hot — allow to cool.
How to read it — check button recall: Hold the remote's CHECK button about 5 seconds to recall the last stored H/F code, read on the indoor unit / remote display. (Panasonic service manual PAPAMY2101002CE, §18.3–18.4)
Source: Panasonic SM PAPAMY2101002CE §18.3 Error Codes Table / §18.4
Likely causes
- Low refrigerant charge / leak
- Expansion valve underfeeding
- Restriction in the circuit
Source: Panasonic SM PAPAMY2101002CE §18.3 Error Codes Table / §18.4
UK models this code applies to
Tap yours to open F97 on that machine.
Wall-mounted4
Cassettes20
Ducted26
Ceiling suspended16
Indoor and outdoor pairs5
Outdoor units21
F97 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted77
Ducted10
Floor consoles8
Indoor and outdoor pairs8
Multi-split outdoor units3
Now the harder half: proving what caused it
F97 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F97 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F114-way (reversing) valve fault
- F90Power factor correction (PFC) protection
- F91Refrigeration cycle abnormality
- F93Compressor rotation failure
- F95Cooling high-pressure abnormality
- F96IPM (power module) overheating
- F98Input over-current protection
- H11Indoor/outdoor communication fault
- H12Indoor unit capacity unmatched · Panasonic Professional 24/7 YKEA…
- H14Indoor intake air sensor abnormality