Panasonic air conditioning F93 fault code
Panasonic air conditioning
What the Panasonic air conditioning F93 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The inverter detects the compressor is not rotating correctly (position detection).
Safety: Safe isolation before disconnecting the compressor or testing the inverter board.
How to read it — check button recall: Hold the remote's CHECK button about 5 seconds to recall the last stored H/F code, read on the indoor unit / remote display. (Panasonic service manual PAPAMY2101002CE, §18.3–18.4)
Source: Panasonic SM PAPAMY2101002CE §18.3 Error Codes Table / §18.4
Likely causes
- Compressor winding fault / seizure
- Loose compressor connection
- Inverter PCB fault
- Liquid slugging / flooded start
Source: Panasonic SM PAPAMY2101002CE §18.3 Error Codes Table / §18.4
UK models this code applies to
Tap yours to open F93 on that machine.
Wall-mounted4
Cassettes20
Ducted26
Ceiling suspended16
Indoor and outdoor pairs5
Outdoor units21
F93 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted77
Ducted10
Floor consoles8
Indoor and outdoor pairs8
Multi-split outdoor units3
Now the harder half: proving what caused it
F93 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F93 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F114-way (reversing) valve fault
- F90Power factor correction (PFC) protection
- F91Refrigeration cycle abnormality
- F95Cooling high-pressure abnormality
- F96IPM (power module) overheating
- F97Compressor overheating
- F98Input over-current protection
- H11Indoor/outdoor communication fault
- H12Indoor unit capacity unmatched · Panasonic Professional 24/7 YKEA…
- H14Indoor intake air sensor abnormality