Mitsubishi Electric air conditioning 6-FLASH fault code
Mitsubishi Electric air conditioning
What the Mitsubishi Electric air conditioning 6-FLASH fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Communication between indoor and outdoor units is lost for 3 minutes.
Safety: Safe isolation before opening terminal covers — mains present on S1/S2/S3.
How to read it — led flash counts: M-Series outdoor units self-diagnose as an LED flash count on the outdoor inverter board; the indoor unit reports via its lamp flashes (failure-mode recall). The SAME flash count can mean different things depending on whether the unit is dead or still running, so note the operating condition with the count. (Mitsubishi Electric service manual OBH789, §12-3 check table)
Source: OBH789 §12-3 no.4, §12-5 M
Likely causes
- Miswired or loose interconnect
- Supply fault
- Indoor or outdoor PCB fault
- Stored MXZ multi-connection history
Source: OBH789 §12-3 no.4, §12-5 M
UK models this code applies to
Tap yours to open 6-FLASH on that machine.
Wall-mounted209
Cassettes71
Ducted79
Ceiling suspended29
Floor consoles7
Floor-standing11
Indoor and outdoor pairs9
Multi-split outdoor units15
Outdoor units193
6-FLASH on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted54
Indoor and outdoor pairs3
Outdoor units34
Now the harder half: proving what caused it
6-FLASH names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 6-FLASH on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- 3-FLASHcompressor stops
- 3-FLASH-IUSerial signal from the outdoor unit not received
- 3-FLASH-RUNhigh-pressure / defrost frequency drop
- 4-FLASHunit stops
- 5-FLASHcompressor stops
- 7F-INDOORindoor lamp 7-flash
- 10-FLASHOutdoor fan motor fault
- 11-FLASHClosed stop valve detected by compressor current
- 11-FLASH-IUno rotation feedback
- 12-FLASH-IUnonvolatile memory fault