Mitsubishi Electric air conditioning 3-FLASH-IU fault code
Mitsubishi Electric air conditioning
What the Mitsubishi Electric air conditioning 3-FLASH-IU fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The indoor unit receives no serial signal from the outdoor unit for up to 6 minutes (recall mode: 3 flashes). OBH788 §10-6 'How to check miswiring and serial signal error'.
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
How to read it — led flash counts: M-Series outdoor units self-diagnose as an LED flash count on the outdoor inverter board; the indoor unit reports via its lamp flashes (failure-mode recall). The SAME flash count can mean different things depending on whether the unit is dead or still running, so note the operating condition with the count. (Mitsubishi Electric service manual OBH789, §12-3 check table)
Source: OBH788 failure-mode recall table + §10-5/10-6
Likely causes
- Miswired or broken interconnect
- Supply fault
- Outdoor control PCB
- Indoor control PCB
Source: OBH788 failure-mode recall table + §10-5/10-6
UK models this code applies to
Tap yours to open 3-FLASH-IU on that machine.
Wall-mounted263
Cassettes71
Ducted79
Ceiling suspended29
Floor consoles7
Floor-standing11
Indoor and outdoor pairs12
Multi-split outdoor units15
Outdoor units227
Now the harder half: proving what caused it
3-FLASH-IU names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 3-FLASH-IU on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- 1-FLASH-IURoom temperature thermistor (RT11) short / open
- 1-FLASH-RUNcurrent-protection frequency drop
- 2-FLASHunit stops and restarts
- 2-FLASH-IUIndoor coil thermistor (RT12/RT13) short / open
- 3-FLASHcompressor stops
- 3-FLASH-RUNhigh-pressure / defrost frequency drop
- 4-FLASHunit stops
- 5-FLASHcompressor stops
- 6-FLASHIndoor/outdoor serial communication fault
- 7F-INDOORindoor lamp 7-flash