Midea PC 02 fault code
Midea air conditioning
What the Midea PC 02 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Temperature protection at the compressor, IPM overheat, or high-pressure protection has operated.
Safety: Discharge pipework and the inverter heat sink run hot — allow to cool; isolate before touching the board.
Source: Midea Breezeless 3D INV service manual SM_FA(GA)_R32 (midea.com), §2.1 error-code table
UK models this code applies to
Tap yours to open PC 02 on that machine.
Wall-mounted12
Cassettes12
Ducted12
Ceiling or floor5
PC 02 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted19
Ducted7
Now the harder half: proving what caused it
PC 02 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase PC 02 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- EH 60T1 room sensor error
- EH 61T2 evaporator-centre sensor error
- EL 0CRefrigerant leakage detected
- EL 01Indoor/outdoor communication error
- PC 00IPM malfunction / IGBT over-current protection
- PC 01Over-voltage or under-voltage protection
- PC 03Low-pressure protection
- PC 04Inverter compressor drive error
- PC 08Current overload protection
- PC 40Outdoor main ↔ compressor-drive comms error