Haier F2 fault code
Haier air conditioning
What the Haier F2 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation before disconnecting the compressor or testing the inverter board — capacitors hold charge.
How to read it — indoor display + outdoor led1: Faults show as E/F codes on the indoor display; the outdoor PCB reports the same faults as LED1 flash counts — either surface lands you on the same code. (Haier service manual AS25PBAHRA (Pearl), §10 Service Diagnosis)
Source: Haier service manual AS25PBAHRA (Pearl) §10.3
UK models this code applies to
Tap yours to open F2 on that machine.
Wall-mounted8
Ducted6
Floor-standing1
F2 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted42
Now the harder half: proving what caused it
F2 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F2 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- E2Indoor heat-exchanger sensor failure
- E4Indoor EEPROM error
- E7Indoor ↔ outdoor communication failure (outdoor LED1 × 15)
- E14Indoor DC fan motor fault
- F1IPM (power module) protection (outdoor LED1 × 2)
- F4Discharge temperature overheat protection (outdoor LED1 × 8)
- F12Outdoor EEPROM error (outdoor LED1 × 1)
- LED6Supply over/under-voltage
- LED9Outdoor DC fan motor fault
- LED10Defrost temperature sensor failure