Bosch Compress A01-811 fault code
Bosch Compress heat pumps
What the Bosch Compress A01-811 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
DHW provision: thermal disinfection unsuccessful (Bosch's header; also shown as A41 - 4051…4052).
Source: Worcester Bosch user interface HPC 410 manual 6721832682 (2021/02) §8 Unit troubleshooting, Table 25 (PDF p17-18)
Likely causes
- Water drawn from the cylinder constantly (leak or taps open)
- Hot water sensor mounted wrongly or hanging in the air
- DHW priority switched off so heating and DHW run in parallel
- Air in the cylinder heating coil
- Fault in the pipework between heat pump and cylinder
- Cylinder primary pump under-performing
- Losses in the DHW circulation line
- Hot water temperature sensor out of tolerance
- Booster heater output too small for the cylinder volume
First check
Bosch check 1 of 9 — Check if water is possibly being drawn from the DHW cylinder constantly due to a leak or taps being open.
Source: Worcester Bosch user interface HPC 410 manual 6721832682 (2021/02) §8 Unit troubleshooting, Table 25 (PDF p17-18)
UK models this code applies to
Tap yours to open A01-811 on that machine.
Now the harder half: proving what caused it
A01-811 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase A01-811 on your machine →Free, no sign-up. Pick the model: where we hold Bosch's own chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- A01-5378Outdoor unit defrost failure
- A01-5522Wrong combination of indoor and outdoor units
- A11-1000System configuration not confirmed
- A11-1010No communication via BUS interface EMS 2
- A11-1037Outside temperature sensor: heating standby mode active
- A11-1038Invalid time/date
- A11-3061…3064No communication with mixer module (3061 = heating circuit 1 … 3064 =…
- A11-3091…3094Room temperature sensor defective (3091 = heating circuit 1 … 3094 =…
- A11-6004No communication with solar module
- A31…A34-3021…3024Heating circuit 1…4 flow temperature sensor faulty: standby mode…