Samsung air conditioning C467 fault code
Samsung air conditioning
What the Samsung air conditioning C467 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The inverter sees no compressor connected on one or more phases.
Safety: Safe isolation before disconnecting the compressor or testing the inverter board — capacitors hold charge.
Source: Samsung Wind-Free 2.0 / Quantum 2.0 service manual §3-2-2 outdoor display-error table, cross-checked against Samsung's Error Code Booklet (July 2019)
Likely causes
- Compressor lead disconnected / loose
- Burnt terminal
- Open compressor winding
Source: Samsung Wind-Free 2.0 / Quantum 2.0 service manual §3-2-2 outdoor display-error table, cross-checked against Samsung's Error Code Booklet (July 2019)
UK models this code applies to
Tap yours to open C467 on that machine.
Wall-mounted39
Cassettes35
Ducted24
Ceiling suspended8
Floor consoles8
Floor-standing2
Indoor and outdoor pairs2
Multi-split outdoor units5
Outdoor units1
Now the harder half: proving what caused it
C467 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase C467 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- C441Cooling prohibited: outdoor ambient too low
- C458Outdoor fan motor error
- C461Compressor starting error
- C464IPM over-current
- C466DC-link voltage under/over
- C470Outdoor EEPROM data error (no data)
- C471EEPROM data error (main ↔ inverter)
- C554Gas leak error
- C574Gas shortage error
- C665Drain pump error (where fitted)