Samsung air conditioning C187 fault code
Samsung air conditioning
What the Samsung air conditioning C187 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The self-clean/filter mechanism's feedback signal is missing. Only on models with a motorised filter.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Samsung Wind-Free Comfort service manual DB68-08680A (AR09/12TXFC, AR24TXEA), display-error tables pp.12-13
Likely causes
- Loose, corroded or water-damaged connector on the board
- Supply fault or poor neutral presenting as a board error
- Water ingress / corrosion (outdoor boards)
- Filter drive module / indoor PCB (check the drive connector and mechanism travel first) memory or hardware fault
Source: Samsung Wind-Free Comfort service manual DB68-08680A (AR09/12TXFC, AR24TXEA), display-error tables pp.12-13
UK models this code applies to
Tap yours to open C187 on that machine.
Wall-mounted39
Cassettes35
Ducted24
Ceiling suspended8
Floor consoles8
Floor-standing2
Indoor and outdoor pairs2
Multi-split outdoor units5
Outdoor units1
Now the harder half: proving what caused it
C187 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase C187 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- C142Humidity sensor error
- C143Motion sensor error (where fitted)
- C154Indoor fan motor error
- C161Mixed operation error
- C163Option error
- C203Main ↔ inverter PCB communication timeout
- C221Outdoor temperature (OUT-TH) sensor error
- C231Condenser coil (CON-TH) sensor error
- C251Discharge temperature (DIS-TH) sensor error
- C416Discharge temperature over