LG Therma V CH40 fault code
LG Therma V heat pumps
What the LG Therma V CH40 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
Likely causes
- Loose, corroded or water-damaged connector on the board
- Supply fault or poor neutral presenting as a board error
- Water ingress / corrosion (outdoor boards)
- inverter PCB (compressor current-transformer / CT stage) memory or hardware fault
Source: LG AWHP Service Manual MFL68682007 (© 2020, R32 Therma V) — error codes + component tables; scope: code SET & fan figure whole-range, compressor winding confirmed 12/14/16 kW, thermistor tables part-level
UK models this code applies to
Tap yours to open CH40 on that machine.
Hydro units and cylinders1
Outdoor units36
Now the harder half: proving what caused it
CH40 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase CH40 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- CH27PFC over-current
- CH29Compressor over-current (inverter input over limit)
- CH32Discharge-pipe temperature high
- CH34High-pressure error (condensing pressure high)
- CH35Low-pressure error (evaporating pressure low)
- CH41Inverter discharge-pipe sensor open/short
- CH43High-pressure sensor open/short
- CH44Outdoor air-temp sensor open/short
- CH45Condenser mid-pipe sensor open/short
- CH46Compressor suction-pipe sensor open/short