Kaisai F4 fault code

Kaisai air conditioning

What it means

Outdoor EEPROM parameter error (shows E0 on the indoor unit)

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W, Toshiba approx. 100 Ω 40 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

UK models this code applies to

From the Kaisai service literature we hold (KAISAI FLY Inverter Series B (KWX) R32 service manual, §4 Quick Maintenance by Error Code (p.65, render-verified) + §5 Troubleshooting by Error Code) — not a scraped list.

FLY KWX-09 (KWX-09HRBI / HRBO)FLY KWX-12 (KWX-12HRBI / HRBO)FLY KWX-18 (KWX-18HRBI / HRBO)FLY KWX-24 (KWX-24HRBI / HRBO)FLY KWX-09 (KWX-09KRHI / KRHO)FLY KWX-12 (KWX-12KRHI / KRHO)FLY KWX-18 (KWX-18KRHI / KRHO)FLY KWX-24 (KWX-24KRHI / KRHO)Multi K2OC-18HFN32Multi K3OE-27HFN32Multi K4OB-36HFN32Multi K5OD-42HFN32

Now the harder half: proving what caused it

F4 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.