Hitachi 01300 fault code
Hitachi air conditioning
What the Hitachi 01300 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The indoor control cannot read its stored data. Named 'EEPROM data reading error' on RAK-PSE and 'IC401 data reading error' on RAK-PED — same fault class.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Hitachi Technical Catalogue §9.10 / §10.1.2 Error Code Information (RAK-PSES(W)/RAC-WSE — Hitachi UK; RAK-PED/RAC-WED — Hitachi R32 catalogue), both render-verified
UK models this code applies to
Tap yours to open 01300 on that machine.
Wall-mounted39
Cassettes28
Ducted21
Ceiling suspended7
Ceiling or floor8
Floor-standing8
Outdoor units60
01300 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted13
Cassettes8
Ducted14
Floor consoles6
Indoor and outdoor pairs2
Multi-split outdoor units7
Outdoor units3
Now the harder half: proving what caused it
01300 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 01300 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- 01000Abnormal rotating numbers (indoor fan speed) (code 10)
- 01001Abnormal power source (code 10)
- 01101Fan stop for strong wind (code 11)
- 01200Communication error, indoor ↔ outdoor (code 12) — RAK-PSE models
- 01201Outdoor fan motor fault (code 12)
- 01301EEPROM reading error (code 13)
- 01401Active converter defective (code 14)
- 01501Abnormal PWB circuit (code 15)
- 01601High load stop (code 16)
- 01800Cleaning defective (auto-clean) (code 18) — RAK-PSE models