Grant Aerona P01 fault code

Grant Aerona heat pumps

What it means

Water flow protection

Circulating flow below 8.3 L/min (flow switch trips below 4.6 L/min). The manual calls this THE common commissioning fault — trapped air after filling.

UK models this code applies to

From the Grant service literature we hold (Grant Aerona 290 installation manual DOC0204 Rev 1.8, Table 11-1) — not a scraped list.

Aerona HPR2904 (4 kW)Aerona HPR29065 (6.5 kW)Aerona HPR2909 (9 kW)Aerona HPR29012 (12 kW)Aerona HPR290155 (15.5 kW)

Now the harder half: proving what caused it

P01 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.