Fujitsu General 64 fault code
Fujitsu General air conditioning
What the Fujitsu General 64 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The power-factor-correction circuit on the outdoor board has errored. Check the supply is clean and within range before condemning the board.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Fujitsu General ASEH07/09/12/14KMCG service manual (official UK webstore), error-code table + troubleshooting; cross-checked against SR_AS092EF_01. All 23 codes verified model-specific 2026-07-16.
UK models this code applies to
Tap yours to open 64 on that machine.
Wall-mounted27
Cassettes2
Ducted16
Floor consoles6
64 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted38
Cassettes22
Ducted48
Ceiling suspended13
Now the harder half: proving what caused it
64 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 64 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- 35MANUAL AUTO button error
- 41Room temperature sensor error
- 42Indoor heat-exchanger sensor error
- 51Indoor unit fan motor error
- 62Outdoor unit main PCB error
- 65IPM error
- 71Discharge thermistor error
- 73Outdoor heat-exchanger liquid-outlet thermistor error
- 74Outdoor temperature thermistor error
- 84Current sensor error